Fungere: Omnipolar Switch, Teknologi: Hall Effect, Polarisering: Either, Sensing Range: ±5.5mT Trip, ±1mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 2.5V ~ 3.5V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 20mT Trip, 11mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.6V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 13.5mT Trip, 4mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.6V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 4mT Trip, -4mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 4.2V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 4.4mT Trip, -4.4 Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 2.8V ~ 5.5V,
Fungere: Omnipolar Switch, Teknologi: Hall Effect, Polarisering: Either, Sensing Range: ±5.5mT Trip, ±0.5mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.6V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 6mT Trip, 1mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Special Purpose, Teknologi: Hall Effect, Sensing Range: Programmable, Spænding - Forsyning: 4.2V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 17mT Trip, -17mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.8V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 5mT Trip, 5mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 4.2V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 9.5mT Trip, -9.5mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.8V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: Programmable, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 8mT Trip, 1mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Omnipolar Switch, Teknologi: Hall Effect, Polarisering: Either, Sensing Range: ±7mT Trip, ±1mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 2.4V ~ 5.5V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 11mT Trip, 4.5mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Special Purpose, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 69% Trip, 31% Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 4V ~ 24V,
Fungere: Special Purpose, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 65% Trip, 35% Release, Testtilstand: 25°C, Spænding - Forsyning: 4V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 9mT Trip, -9mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 4.2V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 8mT Trip, -8mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 3.5mT Trip, 2.5mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 2.8V ~ 5.5V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 6mT Trip, 1mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.5V ~ 24V,
Fungere: Unipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: Programmable, Spænding - Forsyning: 4.2V ~ 24V,
Fungere: Latch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 30mT Trip, -30mT Release, Testtilstand: -40°C ~ 150°C, Spænding - Forsyning: 3.8V ~ 24V,
Fungere: Bipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 7.5mT Trip, -7.5mT Release, Testtilstand: 25°C, Spænding - Forsyning: 4.5V ~ 18V,
Fungere: Bipolar Switch, Teknologi: Hall Effect, Polarisering: South Pole, Sensing Range: 2.5mT Trip, -2.5mT Release, Testtilstand: -40°C ~ 85°C, Spænding - Forsyning: 3.6V ~ 24V,